[image_rotator folder=”/wp-content/uploads/3U Dimmer látvány FLX2.1″]
Our newest development based on the feedbacks from our theater technicals, consultants and installers. We implemented their requests into a new conception of dimming cabinet system based on our previous MS rack solution. We consider at the design to have cost-effective flexible solution for the requires of the 21th century at the stage lightings. This new dimmer cabinet system is available to use as a full dimmer unit for classical filaments or a power distributor for moving heads and LED lights or combination of these.
SKU:
MS2Main features
- Rittal made enclosure
- Up to 120 channel per cabinet (10 bays in total)
- Mains input via cooper rails (bus bar, 3×400A or 3×630A)
- Each bay is protected with HRC fuses
- Free-stand construction with only 62cm × 62cm footprint
- Service door on the backsite for wiring
- Separate bays for 12-channel, 6-channel and 3-channel dimmers
- All our made 3U-heigh dimmers and relay packs are useable into the cabinet (with MS2 variation)
- Slots are moving on roller balls for easy install
- Output protections can be MCBs (1P, 1P N or 2P) or RCBOs
- Blank cover set for empty bays
- Easy upgrade for non-using bays
- Output connections via DIN mounted screw terminals
Orderable slots
- FLX-12xx-MS2 (12-channel FLX dimmer/relay combo)
- FLX-625-MS2 (6×5,7kW FLX dimmer/relay combo)
- PRO2-12xx-MS2 (12-channel PRO2 dimmer)
- PRO2-625-MS2 (6×5,7kW PRO2 dimmer)
- xLite-12xx-MS2 (12-channel xLite dimmer)
- xLite-363-MS2 (3×15kW xLite dimmer)
- RP-12xx-MS2 (12-channel relay)
Where ’xx’ means the output current per channel
Orderable output protection per each channel
- MSO-1PN 1P N MCBs for all outputs
- MSO-RCBO Single module size 1P N 30mA RCBO
- MSO-2P 2P MCBs for all outputs (for IT DELTA mains)
MS2 Dimmer Cabinet System
Mains | 3P+N+PE (230 V/400 V Star 50 or 60 Hz max. 3×400 A or 3×630 A |
Output channels numbers and output current | Up to 120 channel (10A, 13A, 16A, 25A or 63A, depends on the dimmer type) |
Protection of slots | HRC fuses for each bays (D02 40A or 63A per phase, depends on slot type) |
Corrosion protection | Electrostatic sintering (RAL9005 and RAL7035) |
Operating temperature | 0 °C to 35 °C (RH: 0-90%, non-condensing) |
Dimensions | 620×2000×620 (W×H×D in mm) Package dimensions: 640×2020×640 (W×H×D in mm) |
Weight | 100-150 kg (net, depends on bay types and mains input, without slots) |